MultiTek AC Voltage Transducer

SELECTION GUIDE
M100-VA1 1 ph. self powered ave. sensing RMS calibrated
M100-VL1 1 ph. aux powered ave. sensing RMS calibrated
M100-VR1 1 ph. aux powered true RMS sensing RMS cal.
M100-VA3 3 ph. self powered ave. sensing RMS calibrated
M100-VL3 3 ph. aux powered ave. sensing RMS calibrated

TYPICAL APPLICATIONS
The M100 series voltage transducers are designed to measure A.C. Voltage in single and 3 phase system. They convert the A.C. Signal to a D.C. Output that is directly proportional to the input signal.
The M100-VA1 VA3 are self powered (i.e. no auxiliary required) average sensing RMS calibrated voltage transducers, mA and voltage outputs are available.
The M100-VL1 VL3 are average sensing RMS calibrated, live zero voltage transducers. Auxiliary is required to provide power so that 4mA output signal is present when the input is zero.
The M100-VR1 is true RMS sensing RMS calibrated allowing measurement of distorted waveforms of up to 9th harmonic with a crest factor of 5. The VR1 is typically used in voltage measurement where distorted waveform is common such as thyristor drives.
The above units are used to measure voltage in energy management systems, switchboards, generator and telemetery controls. Isolation of 4kV is provided between the input and output signal, allowing the ouput to be fed to conventional analogue meters, digital meters, PLC, and computer systems.

ORDERING INFORMATION
Product Code Input In Output Aux Freq. Options
M100-VA1 230V 4-20mA 230V 50Hz

OPTIONS
1. Non standard inputs / outputs only as far as technically acceptable.
2. A.C. Auxiliary in range 57.7 to 450 volts
3. Calibration at nominal Hz 35.....450Hz
4. Calibration at temperature other than 23°C
TECHNICAL SPECIFICATION
INPUT
Rated value Un 57.8 <100 / 110 <600 V
Power consumption <1.5 VA (VA1, VA3)
<1 VA (VL1, VL3, VR1)
Working range 15-125% Un (VA1, VA3)
0-125% Un (VL1, VL3, VR1)
Rated Frequency 50 / 60 / 400 Hz
Frequency influence 0.005 % / Hz
Overload continuous 1.5 x Un
Overload for 1 sec. 4 x Un (VL1 VL3 VR1 )
2 x Un (VA1 VA3)

OUTPUT
Rated value mA 0-1/5/10/20mA (VA1, VA3)
Rated value mA 1/5/10/20 & 4-20mA (VR1)
Rated value mA 4-20mA (VL1)

Rated Value volts 0-5 / 10 V (VA1, VA3)
Rated value volts 0-5 / 10 & 1-5 V (VR1)
Rated value volts 1-5 V (VL1 VL3)

ADJUSTMENT
Zero No adjustment (VA1,VA3)
Zero ± 2% (VR1,VL1)
Span ± 10% (VA1,VA3,VR1,VL1,VL3)

AUXILIARY
A.C. Voltage 115 / 230 / 400 V
(± 25% / 45-65Hz / <2 VA)
D.C. Voltage 24 / 48 / 110 V (± 20% /
galvanically isolated / < 3 W)
Note M100-VA1 & VA3 are self powered.

WEIGHT & CASE SIZE
M100-VA1 Approx. 0.3 kg. 55mm case
M100-VL1,VR1 Approx. 0.4 kg. 55mm case
M100-VA3 Approx. 0.6 kg. 100mm case
M100-VL3 Approx. 0.7 kg. 100mm case

What are you looking for? | Let us help | 800-523-9194 | request@pc-s.com
What is your Challenge,
Need Description or Goal?
*First & Last Name:  
*E-Mail & Phone:  
*Company:
Address:
*City & State:  
*Zip Code & Country:  
Much appreciated...what engine,
site, or source referred you?
Searched words or other?