Multitek M560 Multifunction Transducer
Specifications
Back to M560
INPUT Rated Un Direct connected voltages between 57.8 and 600 v. Standard voltages offered :- 63.5/110 V, 69.3 / 120 V, 120 / 208 V, 220/380 V, 230 / 400 V, 240 / 415 V, 277 / 480 V, for 3 ph 4 w 110 V, 120 V, 380 V, 400 V, 415 V, 440V, 480 V, 3 ph 3 w Range 2-120% Un Burden 0.5VA per phase Overload 1.5 x Un continuous 4 x Un for 1 second Rated In 1 or 5 amp Range 0-120% Burden 0.5VA per phase Overload 4 x In continuous 50 x In for 1 second Frequency 50 / 60 Hz nominal range 45/65Hz SYSTEMS M560-AT1 Single phase M560-AT1-3 Single phase 3 wire M560-AT4 3 phase 3 wire unbalanced load M560-AT9 3 phase 4 wire unbalanced load ACCURACY Specified@ 23 °C 10%-Un 10%-In Parameters unless stated Class 0.3% to IEC 688 Volts and Amps Class 0.25% to IEC 688 Frequency Class 0.1Hz to IEC 688 Power Factor Class 1.0% to IEC 688 Active Energy 1% of reading IEC 1036 Reactive Energy 1% of reading IEC 1036 ANALOGUE OUTPUTS 3 outputs programmable to any 3 parameters. (except energy measurements W.h VAr.h VA.h A.h) Rated value (software selectable) 0-1mA into <10kOhm load 0-5mA into <2kOhm load 0-10mA into <1kOhm load 0-20mA into <0.5kOhm load 4-20mA into <0.5kOhm load 0-10 volts >1kOhm load Accuracy is relative to a standard 20mA or 10V output. When outputs are specified on order, the accuracy will applicable to that output. Load influence <0.1% Ripple <0.5% peak-peak at full load Response time <400 msec for 0-99% at full load Overload <2 x rated value at full load No load voltage <18 volts |
AUXILIARY AC voltage 115V, 230V or 277V (±15%) DC voltage 12 / 24 / 48 / 110 / 125 volts RELAY OUTPUT (optional) Pulsed output W.h or VAr.h or VA.h or A.h User progammable import or export COMMUNICATION Serial communication RS485 output Modbus protocol Baud Rate Programmable 2400,4800,9600 and 19200 Parity Odd, Even or No parity Auto Detection RS485 ENVIRONMENTAL Working Temperature 0 to +60 deg C Storage Temperature -30 to +65 deg C Temperature Coefficient 0.01% per deg C Relatively Humidity 0-95% non condensing Warm up time 1 min. Shock 20G in 3 planes ENCLOSURE Fixing Snap on to Din rail 35 x 7.5mm complies with DIN-EN 50022 Mounting Any position Enclosure Code Case IP 50 / terminals IP30 Complies with IEC 529 BS5490 DIN 40050 APPLIED STANDARDS General IEC 688 BSEN60688, BS4889, IEC 359 EMC Emissions BSEN50081/1 Immunity BSEN50082/2 Safety IEC1010, BSEN601010 INSULATION Test Voltage 4kV RMS 50Hz for 1 min between input, case, auxiliary, RS485 3kV RS485 / 1.5kV Relay Impulse Test EMC 5kV transient complying with IEC 801/EN 55020 HF Surge withstand IEC 801 / EN55020 ANSI C37.90A Interference EHF 2.5kV 1MHz complying with IEC255-4 Protection Class II Complying with IEC348 APPROVALS UL. C-UL, CSA Pending |