Multitek M560 Multifunction Transducer

Specifications
Back to M560

INPUT
Rated Un Direct connected voltages between 57.8 and 600 v.
Standard voltages offered :-
63.5/110 V, 69.3 / 120 V, 120 / 208 V, 220/380 V, 230 / 400 V, 240 / 415 V, 277 / 480 V, for 3 ph 4 w 110 V, 120 V, 380 V, 400 V, 415 V, 440V, 480 V, 3 ph 3 w
Range 2-120% Un
Burden 0.5VA per phase
Overload 1.5 x Un continuous 4 x Un for 1 second
Rated In 1 or 5 amp
Range 0-120%
Burden 0.5VA per phase
Overload 4 x In continuous 50 x In for 1 second
Frequency 50 / 60 Hz nominal range 45/65Hz

SYSTEMS
M560-AT1 Single phase
M560-AT1-3 Single phase 3 wire
M560-AT4 3 phase 3 wire unbalanced load
M560-AT9 3 phase 4 wire unbalanced load

ACCURACY
Specified@ 23 °C 10%-Un 10%-In
Parameters unless stated Class 0.3% to IEC 688
Volts and Amps Class 0.25% to IEC 688
Frequency Class 0.1Hz to IEC 688
Power Factor Class 1.0% to IEC 688
Active Energy 1% of reading IEC 1036
Reactive Energy 1% of reading IEC 1036

ANALOGUE OUTPUTS
3 outputs programmable to any 3 parameters. (except energy measurements W.h VAr.h VA.h A.h)
Rated value (software selectable)
0-1mA into <10kOhm load
0-5mA into <2kOhm load
0-10mA into <1kOhm load
0-20mA into <0.5kOhm load
4-20mA into <0.5kOhm load
0-10 volts >1kOhm load
Accuracy is relative to a standard 20mA or 10V output.
When outputs are specified on order, the accuracy will applicable to that output.
Load influence <0.1%
Ripple <0.5% peak-peak at full load
Response time <400 msec for 0-99% at full load
Overload <2 x rated value at full load
No load voltage <18 volts
AUXILIARY
AC voltage 115V, 230V or 277V (±15%)
DC voltage 12 / 24 / 48 / 110 / 125 volts

RELAY OUTPUT (optional)
Pulsed output W.h or VAr.h or VA.h or A.h User progammable import or export

COMMUNICATION
Serial communication RS485 output Modbus protocol
Baud Rate Programmable
2400,4800,9600 and 19200
Parity Odd, Even or No parity
Auto Detection RS485

ENVIRONMENTAL
Working Temperature 0 to +60 deg C
Storage Temperature -30 to +65 deg C
Temperature Coefficient 0.01% per deg C
Relatively Humidity 0-95% non condensing
Warm up time 1 min.
Shock 20G in 3 planes

ENCLOSURE
Fixing Snap on to Din rail
35 x 7.5mm complies with DIN-EN 50022
Mounting Any position
Enclosure Code Case IP 50 / terminals IP30 Complies with IEC 529 BS5490 DIN 40050

APPLIED STANDARDS
General IEC 688 BSEN60688, BS4889, IEC 359 EMC Emissions BSEN50081/1 Immunity BSEN50082/2
Safety IEC1010, BSEN601010

INSULATION
Test Voltage 4kV RMS 50Hz for 1 min between input, case, auxiliary, RS485 3kV RS485 / 1.5kV Relay
Impulse Test EMC 5kV transient complying with IEC 801/EN 55020 HF Surge withstand IEC 801 / EN55020 ANSI C37.90A Interference EHF 2.5kV 1MHz complying with IEC255-4
Protection Class II Complying with IEC348

APPROVALS
UL. C-UL, CSA Pending

 

 